Metric thread chart
ISO general-purpose metric threads use a 60-degree profile (ISO 68-1). ISO 262 selects the coarse and fine pitches in everyday use; ISO 724 gives the basic diameters. The coarse pitch is the default when a drawing shows only “M12.”
ISO 262 coarse series
Basic pitch diameter is d2 = d − 0.64952P (ISO 68-1 / ISO 724). The usual tap drill for about 75% engagement is the common recommended metric size near d − P.
| Thread | Pitch P (mm) | Basic major d (mm) | Basic pitch dia. d2 (mm) | Usual 75% tap drill (mm) |
|---|---|---|---|---|
| M3 | 0.50 | 3.00 | 2.675 | 2.5 |
| M4 | 0.70 | 4.00 | 3.545 | 3.3 |
| M5 | 0.80 | 5.00 | 4.480 | 4.2 |
| M6 | 1.00 | 6.00 | 5.350 | 5.0 |
| M8 | 1.25 | 8.00 | 7.188 | 6.8 |
| M10 | 1.50 | 10.00 | 9.026 | 8.5 |
| M12 | 1.75 | 12.00 | 10.863 | 10.2 |
| M14 | 2.00 | 14.00 | 12.701 | 12.0 |
| M16 | 2.00 | 16.00 | 14.701 | 14.0 |
| M18 | 2.50 | 18.00 | 16.376 | 15.5 |
| M20 | 2.50 | 20.00 | 18.376 | 17.5 |
| M24 | 3.00 | 24.00 | 22.051 | 21.0 |
Pitches: ISO 262 coarse series. Basic diameters: ISO 724, with d2 = d − 0.64952P rounded to three decimal millimetres. Tap drills are the usual recommended sizes (ISO 2306 / shop practice) for about 75% engagement, not a substitute for a drawing note or a tap manufacturer’s chart.
Selected ISO 262 fine pitches
| Thread | Fine pitch P (mm) | Basic pitch dia. d2 (mm) | Approx. 75% estimate d − P (mm) |
|---|---|---|---|
| M8 × 1 | 1.00 | 7.350 | 7.0 |
| M10 × 1.25 | 1.25 | 9.188 | 8.75 |
| M12 × 1.5 | 1.50 | 11.026 | 10.5 |
| M16 × 1.5 | 1.50 | 15.026 | 14.5 |
| M20 × 1.5 | 1.50 | 19.026 | 18.5 |
Fine pitches from ISO 262. The last column is the simple d − P estimate; use a recommended metric drill near that value, and confirm against the tap maker when a percentage of thread is specified.
Sources
- ISO 262, Selected sizes for screws, bolts and nuts, coarse and fine pitch series.
- ISO 68-1 and ISO 724, basic profile and basic dimensions. Pitch diameter d2 = d − 0.64952P.
- Recommended tapping drill sizes in common metric practice, consistent with ISO 2306-style recommendations for a 75%-class engagement (often d − P, rounded to a standard millimetre drill).
Disclaimer: These pages are reference charts and planning tools only. They are not a substitute for the published standard, a manufacturer's installation instructions, or an engineer's specification. Torque figures are advisory estimates, not values prescribed by ISO 898-1. US customary charts and UK-only fixing names are kept on separate pages and are never mixed into the same rule. Bolt Reference does not sell fasteners, inspect joints, or certify assemblies.