Pilot hole size chart

A pilot (lead) hole lets a wood screw or lag screw cut a clean thread without splitting the work. The official guidance is a percentage of a diameter, not a single mandatory drill letter. The drills in the tool are starting points. This page is for wood and lag screws, not for masonry wall plugs or UK coach screws.

Look up a starting-point pilot

The published rules

The USDA Forest Products Laboratory Wood Handbook describes wood-screw lead holes of about 70% of the root (core) diameter in softwoods and about 90% in hardwoods. Root diameter is the core between the threads, not the basic major diameter in the wood-screw chart.

For lag screws that meet ASME B18.2.1, the American Wood Council National Design Specification for Wood Construction (2018) section 12.1.4.2 requires:

  • A clearance hole for the unthreaded shank, the same diameter as the shank and as deep as that shank.
  • A lead hole for the threaded portion, with diameter 40–70% of the shank in wood with G ≤ 0.5, 60–75% where 0.5 < G ≤ 0.6, and 65–85% where G > 0.6, using the larger end of each range for larger lags, and at least as deep as the threaded length.

NDS 12.1.4.3 allows omitting lead or clearance holes for 3/8 in and smaller lags loaded primarily in withdrawal in wood with G ≤ 0.5 if edge and end distances prevent unusual splitting. Turn a lag with a wrench; do not drive it with a hammer (12.1.4.4).

The starting-point drills in the tool are nearest practical bits inside those rules. They are not table cells in the NDS or a USDA chart. Test in a scrap of the same board. UK coach screws are a different product standard (DIN 571); do not copy these US lag percentages onto that page’s rule without the timber designer’s guidance.

Sources

  • USDA Forest Products Laboratory, Wood Handbook: Wood as an Engineering Material, chapter on fastenings, lead-hole guidance of about 70% of root diameter in softwoods and about 90% in hardwoods. Public USDA / Forest Service edition: Wood Handbook, Chapter 7 — Fastenings (and the current handbook chapter corresponding to that text).
  • American Wood Council, National Design Specification for Wood Construction (2018) with Commentary, 12.1.4 Lag Screws, including 12.1.4.2 lead-hole percentages and 12.1.4.3 / 12.1.4.4. Lag screws are those meeting ANSI/ASME B18.2.1.

Disclaimer: These pages are reference charts and planning tools only. They are not a substitute for the published standard, a manufacturer's installation instructions, or an engineer's specification. Torque figures are advisory estimates, not values prescribed by ISO 898-1. US customary charts and UK-only fixing names are kept on separate pages and are never mixed into the same rule. Bolt Reference does not sell fasteners, inspect joints, or certify assemblies.